-------- Original Message --------
069
NOUS41 KWBC 152010
PNSWSH
PUBLIC INFORMATION STATEMENT...COMMENT REQUEST
NATIONAL WEATHER SERVICE HEADQUARTERS WASHINGTON DC
410 PM EDT MON MAR 15 2010
TO: SUBSCRIBERS
-FAMILY OF SERVICES
-NOAA WEATHER WIRE SERVICE
-EMERGENCY MANAGERS WEATHER INFORMATION NETWORK
-NOAAPORT
-OTHER NWS PARTNERS...USERS AND EMPLOYEES
FROM: RICHARD J. VOGT
DIRECTOR...WSR-88D RADAR OPERATIONS CENTER
SUBJECT: SOLICITING COMMENTS BY APRIL 20 2010 ON NWS PLANS
FOR AN OPERATIONAL FIELD TEST OF AVSET CONTROLLED
WSR-88D VOLUME SCANNING: EFFECTIVE JULY 2010
THE NWS IS PLANNING AN OPERATIONAL FIELD TEST OF THE
AUTOMATED VOLUME SCAN EVALUATION AND TERMINATION /AVSET/
ALGORITHM AT EIGHT WEATHER SURVEILLANCE RADAR-
1988...DOPPLER /WSR-88D/ BUILD 12 RADAR PRODUCT GENERATOR
FIELD SITES STARTING NO EARLIER THAN JULY 15 2010 AND
ENDING JANUARY 31 2011. THE PURPOSE OF THE TEST IS TO
ENSURE AVSET FUNCTIONALITY INTEGRATES INTO WSR-88D FIELD
OPERATIONS. IF THE PROPOSED TEST IS APPROVED...THE TEST
SITES WILL ISSUE A FREE TEXT MESSAGE IN ADVANCE OF USING
AVSET THE FIRST TIME.
THE NWS IS REQUESTING COMMENTS THROUGH APRIL 20 2010 ON THE
PROPOSED OPERATIONAL FIELD TEST. SEND COMMENTS TO:
TIM.D.CRUM@xxxxxxxx
MICHAEL.ISTOK@xxxxxxxx
THE PROPOSED WSR-88 AVSET OPERATIONAL TEST SITES ARE:
KCCX STATE COLLEGE PA
KEMX TUCSON AZ
KGGW GLASGOW MT
KGLD GOODLAND KS
KIND INDIANAPOLIS IN
KLWX STERLING VA
KMLB MELBOURNE FL
KTLX OKLAHOMA CITY OK
AVSET HAS BEEN DEVELOPED TO MEET WSR-88D AGENCY
REQUIREMENTS FOR FASTER VOLUME COVERAGE PATTERN /VCP/
UPDATES...ESPECIALLY IN SEVERE WEATHER SITUATIONS. THE
BASIC PREMISE OF THE AVSET FUNCTION IS TO TERMINATE A
VOLUME SCAN AFTER THE WSR-88D HAS SCANNED ALL OF THE
ELEVATIONS WITH IMPORTANT RETURNS. THE NET EFFECT OF AVSET
IS TO SHORTEN THE ELAPSED TIME BETWEEN DATA COLLECTION ON
LOW ELEVATION ANGLES. WHEN AVSET IS OPERATING...THE VCP
NUMBER DOES NOT CHANGE... THE ELEVATION ANGLES EXECUTED
BEFORE THE TERMINATION OF THE VCP DO NOT CHANGE...AND
VOLUMETRIC PRODUCTS ARE PRODUCED. THE AVSET FUNCTION:
EVALUATES THE RETURN ON EACH ELEVATION ABOVE 5 DEG AND
TERMINATES THE VCP IF THE AREAL COVERAGE THRESHOLDS ARE
NOT MET.
SHORTENS THE ELAPSED TIME BETWEEN DATA COLLECTION ON LOW-
ELEVATION ANGLES AND GENERATION OF VOLUME-BASED PRODUCTS
DURING PERIODS WHEN LITTLE OR NO DATA ARE AVAILABLE ON
HIGHER TILTS.
RESULTS IN FASTER VCP UPDATES WITHOUT IMPACTING THE
QUALITY AND ACCURACY OF THE BASE DATA ESTIMATES.
DURING THE TEST PERIOD...SITE OPERATORS WILL BE ASKED TO
USE AVSET AS OFTEN AS THEY WISH. THE DEFAULT STATE OF THE
AVSET FUNCTION IS /DISABLED/. THUS OPERATORS MUST MANUALLY
ACTIVATE AVSET EACH TIME USE IS DESIRED. AVSET IS
AUTOMATICALLY DISABLED WHEN A CLEAR AIR COVERAGE
PATTERN...VCP 31 OR VCP32...IS INVOKED.
THE WSR-88D RADAR OPERATIONS CENTER HAS CONDUCTED EXTENSIVE
OFF-LINE AVSET TESTING. AVSET DOES NOT ADVERSELY AFFECT
NEXRAD AGENCY SYSTEMS AND NWS BELIEVES THERE WILL BE LITTLE
OR NO ADVERSE IMPACT OF AVSET ON USER SYSTEMS. HOWEVER
AVSET WILL INCREASE NARROWBAND AND LEVEL II COMMUNICATIONS
LOADING. SINGLE-SITE NARROWBAND COMMUNICATIONS AND LEVEL II
LOADING CAN INCREASE UP TO 30 PERCENT /WORST CASE/ WITH A
FAST VCP. USING AVSET IS AN OPERATOR-SELECTABLE OPTION.
THUS THE OVERALL NETWORK-WIDE COMMUNICATIONS INCREASES WILL
BE MUCH LESS THAN THE INDIVIDUAL SITE FIGURES.
MORE AVSET DETAILS ARE AVAILABLE UNDER /NEW RADAR
TECHNOLOGY/ AT:
HTTP://WWW.ROC.NOAA.GOV/WSR88D/.
NATIONAL PUBLIC INFORMATION STATEMENTS ARE ONLINE AT
/USE LOWERCASE/:
HTTP://WWW.WEATHE.GOV/OS/NOTIF.HTM
$$
NNNN